<Error>
<ErrorNumber>17046</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: multiple edges detected - verify image position
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This is not an error - it is an informational message only.
</text></DescriptionText>
<DescriptionText><text>
While searching for the edge of the plate, the head "saw" two edges.  The "media x
edge" parameter was set to 2, so this condition is allowed, and the first edge is taken
as the true edge.
</text></DescriptionText>
<DescriptionText><text>
Each time this occurs, the "state imaging double_edge_count" is incremented, and this warning
message is sent to the workstation.  The total count can be checked with the "list stats" command.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The edge of the plate was not well defined, so the registration may be inaccurate.
Check the image position on the media, and re-run the job if necessary.  If this
happens frequently, contact the CreoScitex Response Center.
</text></DescriptionText>
</OperatorAction>
<Cause>
Poorly cut plates
</Cause>
<Cause>
Inconsistant emulsion
</Cause>
<Cause>
Incorrect surface reflectivity setting
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/media_cal_edge.xml</LinkAddress><LinkTitle>NVS: media edge</LinkTitle></Link>
<Link><LinkAddress>../nvs/imaging_state_double.xml</LinkAddress><LinkTitle>NVS: imaging double</LinkTitle></Link>
<Link><LinkAddress>../nvs/media_cal_sr.xml</LinkAddress><LinkTitle>NVS: media sr</LinkTitle></Link>
<Link><LinkAddress>../nvs/hdm_cal_sr.xml</LinkAddress><LinkTitle>NVS: hdm sr</LinkTitle></Link>
<Link><LinkAddress>../commands/list_stats.xml</LinkAddress><LinkTitle>Command: list stats</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:35 2008 PST
</Updated>
<Links>
</Links>
</Error>